VEVOR NL NL
Selecteer het land/de regio, de taal en de valuta van uw voorkeur om te winkelen.
Leveren aan
Your Address
Hallo, Log in
Rekening & Bestelling
Categorieën
Download de VEVOR app
5,00€ korting op de eerste drie bestellingen en volg de bestelling overal!
Scan de QR-code om te downloaden
VEVOR Omvormer Inverter 2.2kw 3hp Vfd Variabele Frequentie Aandrijving Omvormer Competely Soundl Digitale Display Pid Control

Klantbeoordelingen voor VEVOR Omvormer Inverter 2.2kw 3hp Vfd Variabele Frequentie Aandrijving Omvormer Competely Soundl Digitale Display Pid Control

2,2 kW

klanten-reviews

Beoordelingen per functie

  • 4.7
  • 4.5
  • 4.6
  • 4.5
  • Bekijk Meer Minder zien
31 Beoordeling(en)
Wis filters
D D
Works well good product
Easy to configure, good instructions. Would be nice if it had an extension lead for the detachable lcd display. Overall, though well designed and packaged. Thanks!
Rob Rob
Does what it needs to do.
Just got this wired up, easy to follow instructions to get it up and running. I used a kettle lead for the power, stripped and connected to the single phase input. Just a normal 3 core wire to the spindle as I'm going to run the cable along my extraction hose, if you want it in the drag chain or near other low voltage cables you'll need some shielded cable for interference. Just want to connect the earth from the kettle lead to the aircraft plug on my spindle then its ready to go on my machine. Obviously I can't comment on the longevity of the unit, I'll have to come back and update later but I'm very happy with this so far.I'm using this with a Vevor 1.5kw air cooled spindle on a standard Workbee 1015.
Brightsparkey Brightsparkey
Does what it says on the tin
Easy to use and seems to work fine. Fan is noisy but at least airflow is adequate. One thing to be aware of is the external button controls don't function the same as the built in panel for stop/start and rev. The external button must be latched to keep the motor running. I used a 3 way rotary switch in the end. No problems encountered with radio noise or interference, and the controller has good control of the motor start and stop speed. Even though it doesn't have braking, the motor spins down fast enough on my lathe. Not enough mileage to comment on reliability, but it been put through its paces with no signs of distress. Shame these units are discontinued, as I have a couple of other machines that could benefit from one.
gary howell gary howell
Easy to use
Found it easy to use and connect up. I find it to be value for money.
parwood parwood
md
a great product essay to set up out of the box wired up and running am really happy with with it the good thing as i can get intouch if there was ever a problem
DavidJ DavidJ
VFD for pillar drill
Excellent quality unit , does all that is required of it. Only thing is that for a relatively inexperienced engineer set-up proved to be a little complex. Used to enable the use of a 3 phase Pillar drill where only sigle phase available. However achieved and now understand the manual much better. Will buy again for 3 other machines in due course
Steve Steve
Mr
Does what it's supposed to at a great price. Time will tell on reliability but its holding up so far
Spaltman Spaltman
Peter
Hoop verschillende dingen gehoord over deze site maar geen enkel probleem gehad met bestelling en levering. Prima kwaliteit voor een onverslaanbare prijs. Grootste nadeel is het ontbreken van een draaiknop om snel toeren te regelen maar dit was duidelijk op foto's voor de aanschaf dus niet ten nadele van vevor.
Engineer Engineer
Mr
Arrived safely and worked very well.Has all the various functions that I need when I used it to run and regulate my 72 x 2 Belt Grinder
Zrt121 Zrt121
It works Amazing
Bought this to try it, It was a low price, I have a Fobco Star drill with A three Phase motor, and I wanted to power it with 240v power. I rewired the motor To delta 240V , I had to change the setting from 400HZ to 50HZ and the motor starts and runs perfect , It is best to read the whole manual as there are a lot of setting that you can change. I bought the 1.5KW unit and it powered an old 0.33BHP / 0.25KW motor with no problems

Mensen die dit artikel kochten, kochten ook